Sushma calibration & Test Labs Private limited specializes in a variety of dimensional calibration disciplines. Dimension Calibration for that all your instruments provide reliability, precision and traceability of results. Sushma calibration & Test Labs Private limited which is accredited as per ISO 17025 in India, & all Sensors are calibrated as per ISO 376:2011.
We utilize latest technology and have imbibed advanced standards to calibrate equipment with the best possible accuracies. Our services are timely, accurate and results are pronounced via a Calibration Certificate endorsed with the report of all work done and results achieved. When your instrument is due for re-calibration, we will send you a reminder notice.
Benefits Of Dimension Calibration
Calibration of Lever arm, LVDT, Articulated Arm measuring machines(CMM), Depth micrometers, height gauges, Feeler/Gap gauges, Vernier Calipers etc.,
Scope
Item Description | Standard followed / Method Used | Capability | Best CMC |
---|---|---|---|
Angle Measuring Device (Torque Angle Wrench) | Using Optical Encoder & Digital Display Unit by Comparison method | Upto 3000O | |
Articulated Arm Coordinate Measuring Machine (CMM) (a)Effective Diameter Performance (Probing Error) | Using Reference Sphere by comparison based on ASME B89.4.22-2004 | Upto 25mm | |
Articulated Arm Coordinate Measuring Machine (CMM) (b) Single Point Articulated performance (Location Error) | Using Reference Sphere by comparison based on ASME B89.4.22-2004 | Upto 25mm | |
Articulated Arm Coordinate Measuring Machine (CMM) (c) Volumetric Performance | Using Reference Sphere by comparison based on ASME B89.4.22-2004 | 0 to 2.5mm | |
Articulated Arm Coordinate Measuring Machine (CMM) (d)Length Measuring Accuracy | Using Gauge Blocks with Fixture by comparison based on ISO 10360-12 & ISO 10360-2 | 2.5mm | |
Articulated Arm Coordinate Measuring Machine (CMM) (a) Probing Size Error(b)Probing Form Error(c)Articulate Location Error | Using Gauge Blocks with Fixture by comparison based on ISO 10360-12 & ISO 10360-2 | 25,25,25 mm 1, 1 | |
Linear Displacement measuring Systems with Display Units (Optical/Magnetic/LVDT/Capacitive probes) Resolution: | Using Gauge Blocks Calibration Stand/ Micrometer head by Comparison based on ASTM E 2309M-16 | Upto 1m (1000mm) | |
Lever Arm | Using Portable CMM by comparison | Upto 2.5m | |
Height Gauge (Vernier/Dial/Digital) LC | Using Caliper Checker/Gauge Blocks/Long Gauge Blocks by Comparison based on IS 2921 | Upto 600mm | |
Feeler/Gap Gauge | Using Digital Micrometer by comparison | 0 to 2mm | |
External Micrometer(Analog/Digital) | Using Gauge Blocks by comparison based on IS:2967 | Upto 150mm | |
Extensometer/LVDT | Using Calibration System with Micrometer head by comparison based on ASTM E- 83-16, ISO:9513 | 0 to 50mm | |
Extensometer/LVDT | Using Calibration System with Electronic Probe & DRO By Comparison Based on ASTM E-83-16, ISO:9513 | 0 to 50mm | |
Depth Micrometer (Analog/Digital) | Using gauge Blocks by Comparison based on BS: 6468 | 50mm | |
Calipers (Vernier/Dial/Digital) | Using Caliper checker/Gauge Blocks/Long Gauge Blocks by Comparison based on IS:3651(Part 1,2&3) | Upto 600mm |